storage

Ricerca nei post

PERCCLI – Add hotspare disk to diskgroup

perccli /cx[/ex]/sx add hotsparedrive [DGs=<N|0,1,2...>] [enclaffinity] [nonrevertible] This command creates a hot spare drive. You can use the following options to create a hot spare drive: OPTION VALUE RANGE DESCRIPTION dgs Valid drive group number Specifies the drive group to which the hot spare drive is dedicated. enclaffinity Valid enclosure number Specifies the enclosure with which the hot spare is associated. If this option is specified, affinity is set; if it is not specified, there is no affinity. NOTE: Affinity cannot be removed after it is set for a hot spare drive. nonrevertible   Sets the drive as a nonrevertible [...]

by |29 Settembre 2022|Categorie: Server, Tutte le guide|tag = , , , , |0 Commenti

HPE Smart Array Controller – Firmware update tramite SSH VMware ESXi

Obiettivo: Aggiornare il firmware del controller storage HPE Smart Array via SSH da VMware ESXi (6.5 \ 6.7 \ 7.0) Il file in allegato contiene l'aggiornamento alla versione 8.32(D) (5 ott 2020) per i controller Smart Array P220i, P222, P420i, P420, P421, P721m, e P822 Soluzione: Scaricare il file CP044338.zip e decomprimerlo Copiare la cartella CP044338 sull'host ESXi all'interno della cartella "tmp" Connettersi in SSH all'host ESXi e lanciare i seguenti comandi: cd /tmp/CP044338/ chmod +x CP044338.vmexe ./CP044338.vmexe NOTA: nel caso in cui avessimo installato ESXi 7.0, il file da eseguire è CP044338.vmexe64 Selezionare il controller Smart [...]

by |7 Febbraio 2022|Categorie: Server, Tutte le guide|tag = , , , , , , , , |0 Commenti

ESXi – PERCCLI RAID level migration

Obiettivo: Conversione live di un array RAID1 in RAID5  Prerequisiti: Server DELL con controller PERC compatibile con migrazione a caldo OS VMware ESXi 6.5 o superiore Utility PERCCLI installata Soluzione: Collegarsi all'host ESXi in SSH e lanciare i seguenti comandi per avere un riepilogo dei dischi presenti cd /opt/lsi/perccli/ ./perccli /c0 show all Nel mio caso, devo aggiungere al Virtual Disk 0 (visibile da VD LIST) il disco 32:2 (visibile da PD LIST), attulamente in stato UGood. Lanciare il seguente comando per avviare la conversione da RAID1 a RAID5, sostituendo il numero del VD e PD con quelli [...]

by |18 Aprile 2021|Categorie: Server, Tutte le guide, Virtualization|tag = , , , , , , , , |0 Commenti

HPE Smart Storage Administrator (HPE SSA) CLI

Prerequisiti: hpssacli HPE Smart Array storage controller The HPE Smart Storage Administrator CLI (HPE SSACLI) is a commandline-based disk configuration program that helps you configure, manage, diagnose, and monitor HPE ProLiant Smart Array Controllers and now other storage devices as well, such as host bus adapters (HBAs), HPE Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices. HPE SSACLI replaces the existing HP Array Configuration CLI Utility, or ACUCLI, with an updated design and will deliver new features and functionality for various Smart Storage initiatives as they come online. HPE Smart Array Advanced Pack [...]

by |13 Ottobre 2020|Categorie: Server, Tutte le guide, Virtualization|tag = , , , , , , , , , , |0 Commenti

QNAP – Ripristino volume archiviazione offline

Sintomi: Inseriti dischi nel QNAP con volumi esistenti ed il volume non viene montato Riavviato QNAP e sono scomparsi gli storage pool, errore "nessun volume" Perdita generica dello storage Risoluzione: Eseguire il seguente comando per controllare lo stato del RAID: md_checker L'output del comando ci mostra che i RAID metadata ci sono, ed il sistema è in grado di riconoscere un pool RAID, ma è ancora in stato OFFLINE. Lanciamo il seguente comando per scansionare i volumi e portarli online automaticamente: /etc/init.d/init_lvm.sh Ora rilanciamo il comando md_checker e verifichiamo lo stato del pool RAID, ora ONLINE [...]

by |8 Settembre 2020|Categorie: Server, Tutte le guide|tag = , , , , , , , , |0 Commenti

QNAP – Errore FW031 update firmware failed

QNAP TVS-472XT sintomi: Il firmware non si aggiorna con errore "Failed to update the firmware. Insufficient system volume space. Error code: FW031" I volumi non mostrano la capacità reale complessiva. Le impostazioni su QTS non persistono al riavvio. Risoluzione: Collegarsi in SSH al QNAP ed eseguire il seguente comando per eliminare i file di aggiornamento QPKG di terze parti: rm -r /mnt/HDA_ROOT/update_pkg/*  

by |8 Settembre 2020|Categorie: Server, Tutte le guide|tag = , , , , , , , |0 Commenti

HPE Dynamic Smart Array B120i controller driver ESXi

Mi è capitato di installare ESXi 6.7.0 U3 HPE customized sul server HP ML310E G8, configurato con un RAID1 di due hardisk direttamente dall'interfaccia accessibile tramite Intelligent Provisioning. La sorpresa arriva alla creazione del datastore VMFS, come vedete dallo screenshot seguente, ESXi vede i due dischi singoli anzichè il volume RAID1: Vado a vedere la schermata dei controller di archiviazione e non vedo ciò che mi aspettavo, ovvero il controller B120i Soluzione: Connettersi all'host ESXi e copiare il file allegato alla guida tramite SCP 2. Connettersi all'host ESXi tramite SSH ed eseguire il [...]

by |5 Febbraio 2020|Categorie: Server, Tutte le guide, Virtualization|tag = , , , , , , , |0 Commenti